Temperature control units

Temperature control units

Microprocessor temperature monitor system for resin, dry and oil transformers with 4 inputs for 3 wires PT100 probes.

Category: Accessories for transformers
  • Control and showing temperature
  • Control of fan systems
  • Four independent PT100 inputs with three wires
  • Four 250 Volt 10A AC (resistive load) relays of outputs for the
    following functions: pre alarm state, alarm state, fault probe state,
    fan control with hysteresis
  • Manual test relays to simulate or check the reliability of the contact
  • Advanced programming menu: is allowed able, enable and set
    separately each single channel
  • Permanent storing of programmed set of pre-alarm and alarm
    state, on, off fan and history values achieved
  • Assembly on panel by simple fixing jaws
  • Universal power supply (24 ÷ 240) Volt AC/DC 50/60Hz
  • Protocol MODBUS – RTU, RS 485 communication (MT 200 S)
  • Protocol MODBUS – RTU, RS 485 communication and galvanically
    insulated analogical output 4-20 mA (MT 200 C)
  • Protocol MODBUS – TCP, ETHERNET communication (MT 200 E)
  • Tropicalization (optional)
Dimensions

• Enclosure 90x90x115 mm including terminal blocks
• Front panel 96×96 mm
• Weight 0.4 Kg

Power Supply

• Universal power supply (24 ÷ 240) Volt AC/DC ± 10%
50/60Hz, polarity independent, consumption 4 VA

Inputs

• Four analog inputs, temperature detection and control
with PT100 three-wire sensors
in the range from -10 to +200 °C

Outputs

• Four relays 250 V AC 10 A max (resistive load),
1 clean changeover contact
• RS485 Half Duplex serial communication protocol
MODBUS-RTU (MT 200 S)
• RS485 Half Duplex serial communication protocol
MODBUS-RTU – Analog communication 0-20 mA or
4-20 mA (MT 200 C)
• Ethernet communication port, protocol
MODBUS-TCP (MT 200 E)

Features
  • Self-extinguishing NORYL enclosure
  • Front panel protection degree in polycarbonate:
    IP65 (IP66 on request)
  • Rear panel protection degree (terminal side):
    IP20
  • Segment display
  • Automatic display of the value and sensor number
    corresponding to the hottest channel
  • Pre-alarm, alarm, probe failure, ventilation,
    manual operation, historical maximums indications
  • Access to the control unit programming
    directly from the front panel
  • Possibility to independently select
    each single channel
  • Alarm and pre-alarm threshold adjustable in the range
    (-9°C ÷ 199°C)
  • Accuracy ± 1% of the full scale value ± 1 digit
  • Cooling fan management
    on all probes
  • Fan control through hysteresis
    with two temperature values (H and L)
  • Four selectable operating modes
  • Faulty probe recognition, maximum management flexibility
    and ease of programming, validity check
    of the data entered during programming
  • Permanent storage of programmed values
    and data reached by each channel
    (thresholds and historical maximums)
  • Dielectric strength between relay contacts and power line
    2.5 KV AC for 60 seconds
  • Possibility to use the probes for thermostat control
    of the environment
  • Resolution 1°C
  • Control unit operating temperature from -20 °C to +60 °C
  • Maximum admissible ambient humidity 90%
    non-condensing
  • Electrical connections on polarized removable terminals
  • Possibility to manually switch relays through the
    relay test menu to simulate or verify contact reliability
  • Galvanically isolated output 4-20 mA or 0-20 mA
    (MT 200 C)
  • Maximum admissible impedance for current output
    500 Ohm
    Scale 4-20 mA (-10°C 4 mA/+200°C 20 mA)
    Transformation formula: (current in mA temperature
    in °C) Iout = (T+10)/210*16 + 4
    Scale 0-20 mA (-10°C 0 mA/+200°C 20 mA).
    Transformation formula: (current in mA temperature
    in °C) Iout = (T+10)/210*20
  • Certification for use in railway environments according to
    EN-50121-5:2006 standard (MT 200 EN50121-5)
  • IP address, port, subnet, gateway configuration
    via web browser (MT 200 E)
  • Technical manual in five languages
    (other languages on request)
  • Built in compliance with EN61000-6-2:2005 2014/30/EU standard
  • Input filter against interference compliant with
  • Tropicalization (optional)